Goto

Collaborating Authors

 skill assessment


SurgFusion-Net: Diversified Adaptive Multimodal Fusion Network for Surgical Skill Assessment

arXiv.org Artificial Intelligence

Robotic-assisted surgery (RAS) is established in clinical practice, and automated surgical skill assessment utilizing multimodal data offers transformative potential for surgical analytics and education. However, developing effective multimodal methods remains challenging due to the task complexity, limited annotated datasets and insufficient techniques for cross-modal information fusion. Existing state-of-the-art relies exclusively on RGB video and only applies on dry-lab settings, failing to address the significant domain gap between controlled simulation and real clinical cases, where the surgical environment together with camera and tissue motion introduce substantial complexities. This work introduces SurgFusion-Net and Divergence Regulated Attention (DRA), an innovative fusion strategy for multimodal surgical skill assessment. We contribute two first-of-their-kind clinical datasets: the RAH-skill dataset containing 279,691 RGB frames from 37 videos of Robot-assisted Hysterectomy (RAH), and the RARP-skill dataset containing 70,661 RGB frames from 33 videos of Robot-Assisted Radical Prostatectomy (RARP). Both datasets include M-GEARS skill annotations, corresponding optical flow and tool segmentation masks. DRA incorporates adaptive dual attention and diversity-promoting multi-head attention to fuse multimodal information, from three modalities, based on surgical context, enhancing assessment accuracy and reliability. Validated on the JIGSAWS benchmark, RAH-skill, and RARP-skill datasets, our approach outperforms recent baselines with SCC improvements of 0.02 in LOSO, 0.04 in LOUO across JIGSAWS tasks, and 0.0538 and 0.0493 gains on RAH-skill and RARP-skill, respectively.


Model selection and real-time skill assessment for suturing in robotic surgery

arXiv.org Artificial Intelligence

Automated feedback systems have the potential to provide objective skill assessment for training and evaluation in robot-assisted surgery. In this study, we examine methods to achieve real-time prediction of surgical skill level in real-time based on Objective Structured Assessment of Technical Skills (OSATS) scores. Using data acquired from the da Vinci Surgical System, we carry out three main analyses, focusing on model design, their real-time performance, and their skill-level-based cross-validation training. For the model design, we evaluate the effectiveness of multimodal deep learning models for predicting surgical skill levels using synchronized kinematic and vision data. Our models include separate unimodal baselines and fusion architectures that integrate features from both modalities and are evaluated using mean Spearman's correlation coefficients, demonstrating that the fusion model consistently outperforms unimodal models for real-time predictions. For the real-time performance, we observe the prediction's trend over time and highlight correlation with the surgeon's gestures. For the skill-level-based cross-validation, we separately trained models on surgeons with different skill levels, which showed that high-skill demonstrations allow for better performance than those trained on low-skilled ones and generalize well to similarly skilled participants. Our findings show that multimodal learning allows more stable fine-grained evaluation of surgical performance and highlights the value of expert-level training data for model generalization.


Cataract-LMM: Large-Scale, Multi-Source, Multi-Task Benchmark for Deep Learning in Surgical Video Analysis

arXiv.org Artificial Intelligence

The persistent gap between the growing global surgical demand and the trained surgical workforce [1] highlights the need to develop scalable solutions that can enhance training paradigms and optimize workflow management [2]. Computer-assisted surgery (CAS) systems are one approach to address this challenge, with applications in preoperative planning [3], intraoperative guidance [4], and standardized postoperative assessment [5, 6]. The development and validation of these advanced CAS capabilities fundamentally depend on access to large-scale, deeply annotated surgical video datasets that capture procedural phases, instrument-tissue interactions, and technical skill cues [7, 8]. Phacoemulsification cataract surgery is the most common ophthalmic procedure worldwide and the primary intervention for avoidable blindness [9, 10]. This makes it a critical domain for developing data-driven CAS with potential applications in clinical workflows and training [11, 12]. Publicly available datasets for developing CAS in cataract surgery, such as Cataract-1K [13] and CaDIS [14], are limited by their single-center origin and limited annotation scopes [15]. The absence of a multi-source dataset with comprehensive and multi-layered annotations, including objective skill assessments, has limited the development of generalizable multi-task deep learning models [11]. To address this gap, we present the Cataract-LMM (Large-scale, Multi-source, Multi-task) Dataset, a dataset of 3,000 phacoemulsification procedures recorded at two distinct clinical centers (Farabi and Noor Eye Hospitals, Tehran, Iran) between December 2021 and March 2025. The dataset is enriched with four complementary layers of annotations on subsets of the data: 1. Temporal Phase Labels (Phase): Frame-wise annotations for 13 surgical phases across 150 videos to support automated workflow recognition.


Exploring Pre-training Across Domains for Few-Shot Surgical Skill Assessment

arXiv.org Artificial Intelligence

Automated surgical skill assessment (SSA) is a central task in surgical computer vision. Developing robust SSA models is challenging due to the scarcity of skill annotations, which are time-consuming to produce and require expert consensus. Few-shot learning (FSL) offers a scalable alternative enabling model development with minimal supervision, though its success critically depends on effective pre-training. While widely studied for several surgical downstream tasks, pre-training has remained largely unexplored in SSA. In this work, we formulate SSA as a few-shot task and investigate how self-supervised pre-training strategies affect downstream few-shot SSA performance. We annotate a publicly available robotic surgery dataset with Objective Structured Assessment of Technical Skill (OSATS) scores, and evaluate various pre-training sources across three few-shot settings. We quantify domain similarity and analyze how domain gap and the inclusion of procedure-specific data into pre-training influence transferability. Our results show that small but domain-relevant datasets can outperform large scale, less aligned ones, achieving accuracies of 60.16%, 66.03%, and 73.65% in the 1-, 2-, and 5-shot settings, respectively. Moreover, incorporating procedure-specific data into pre-training with a domain-relevant external dataset significantly boosts downstream performance, with an average gain of +1.22% in accuracy and +2.28% in F1-score; however, applying the same strategy with less similar but large-scale sources can instead lead to performance degradation. Code and models are available at https://github.com/anastadimi/ssa-fsl.


Explainable AI for Automated User-specific Feedback in Surgical Skill Acquisition

arXiv.org Artificial Intelligence

Traditional surgical skill acquisition relies heavily on expert feedback, yet direct access is limited by faculty availability and variability in subjective assessments. While trainees can practice independently, the lack of personalized, objective, and quantitative feedback reduces the effectiveness of self-directed learning. Recent advances in computer vision and machine learning have enabled automated surgical skill assessment, demonstrating the feasibility of automatic competency evaluation. However, it is unclear whether such Artificial Intelligence (AI)-driven feedback can contribute to skill acquisition. Here, we examine the effectiveness of explainable AI (XAI)-generated feedback in surgical training through a human-AI study. We create a simulation-based training framework that utilizes XAI to analyze videos and extract surgical skill proxies related to primitive actions. Our intervention provides automated, user-specific feedback by comparing trainee performance to expert benchmarks and highlighting deviations from optimal execution through understandable proxies for actionable guidance. In a prospective user study with medical students, we compare the impact of XAI-guided feedback against traditional video-based coaching on task outcomes, cognitive load, and trainees' perceptions of AI-assisted learning. Results showed improved cognitive load and confidence post-intervention. While no differences emerged between the two feedback types in reducing performance gaps or practice adjustments, trends in the XAI group revealed desirable effects where participants more closely mimicked expert practice. This work encourages the study of explainable AI in surgical education and the development of data-driven, adaptive feedback mechanisms that could transform learning experiences and competency assessment.


End-to-End Deep Learning for Real-Time Neuroimaging-Based Assessment of Bimanual Motor Skills

arXiv.org Artificial Intelligence

The real-time assessment of complex motor skills presents a challenge in fields such as surgical training and rehabilitation. Recent advancements in neuroimaging, particularly functional near-infrared spectroscopy (fNIRS), have enabled objective assessment of such skills with high accuracy. However, these techniques are hindered by extensive preprocessing requirements to extract neural biomarkers. This study presents a novel end-to-end deep learning framework that processes raw fNIRS signals directly, eliminating the need for intermediate preprocessing steps. The model was evaluated on datasets from three distinct bimanual motor tasks--suturing, pattern cutting, and endotracheal intubation (ETI)--using performance metrics derived from both training and retention datasets. It achieved a mean classification accuracy of 93.9% (SD 4.4) and a generalization accuracy of 92.6% (SD 1.9) on unseen skill retention datasets, with a leave-one-subject-out cross-validation yielding an accuracy of 94.1% (SD 3.6). Contralateral prefrontal cortex activations exhibited task-specific discriminative power, while motor cortex activations consistently contributed to accurate classification. The model also demonstrated resilience to neurovascular coupling saturation caused by extended task sessions, maintaining robust performance across trials. Comparative analysis confirms that the end-to-end model performs on par with or surpasses baseline models optimized for fully processed fNIRS data, with statistically similar (p<0.05) or improved prediction accuracies. By eliminating the need for extensive signal preprocessing, this work provides a foundation for real-time, non-invasive assessment of bimanual motor skills in medical training environments, with potential applications in robotics, rehabilitation, and sports.


Dynamic directed functional connectivity as a neural biomarker for objective motor skill assessment

arXiv.org Artificial Intelligence

Objective motor skill assessment plays a critical role in fields such as surgery, where proficiency is vital for certification and patient safety. Existing assessment methods, however, rely heavily on subjective human judgment, which introduces bias and limits reproducibility. While recent efforts have leveraged kinematic data and neural imaging to provide more objective evaluations, these approaches often overlook the dynamic neural mechanisms that differentiate expert and novice performance. This study proposes a novel method for motor skill assessment based on dynamic directed functional connectivity (dFC) as a neural biomarker. By using electroencephalography (EEG) to capture brain dynamics and employing an attention-based Long Short-Term Memory (LSTM) model for non-linear Granger causality analysis, we compute dFC among key brain regions involved in psychomotor tasks. Coupled with hierarchical task analysis (HTA), our approach enables subtask-level evaluation of motor skills, offering detailed insights into neural coordination that underpins expert proficiency. A convolutional neural network (CNN) is then used to classify skill levels, achieving greater accuracy and specificity than established performance metrics in laparoscopic surgery. This methodology provides a reliable, objective framework for assessing motor skills, contributing to the development of tailored training protocols and enhancing the certification process.


Machine Learning-Based Automated Assessment of Intracorporeal Suturing in Laparoscopic Fundoplication

arXiv.org Artificial Intelligence

Automated assessment of surgical skills using artificial intelligence (AI) provides trainees with instantaneous feedback. After bimanual tool motions are captured, derived kinematic metrics are reliable predictors of performance in laparoscopic tasks. Implementing automated tool tracking requires time-intensive human annotation. We developed AI-based tool tracking using the Segment Anything Model (SAM) to eliminate the need for human annotators. Here, we describe a study evaluating the usefulness of our tool tracking model in automated assessment during a laparoscopic suturing task in the fundoplication procedure. An automated tool tracking model was applied to recorded videos of Nissen fundoplication on porcine bowel. Surgeons were grouped as novices (PGY1-2) and experts (PGY3-5, attendings). The beginning and end of each suturing step were segmented, and motions of the left and right tools were extracted. A low-pass filter with a 24 Hz cut-off frequency removed noise. Performance was assessed using supervised and unsupervised models, and an ablation study compared results. Kinematic features--RMS velocity, RMS acceleration, RMS jerk, total path length, and Bimanual Dexterity--were extracted and analyzed using Logistic Regression, Random Forest, Support Vector Classifier, and XGBoost. PCA was performed for feature reduction. For unsupervised learning, a Denoising Autoencoder (DAE) model with classifiers, such as a 1-D CNN and traditional models, was trained. Data were extracted for 28 participants (9 novices, 19 experts). Supervised learning with PCA and Random Forest achieved an accuracy of 0.795 and an F1 score of 0.778. The unsupervised 1-D CNN achieved superior results with an accuracy of 0.817 and an F1 score of 0.806, eliminating the need for kinematic feature computation. We demonstrated an AI model capable of automated performance classification, independent of human annotation.


R-Trans -- A Recurrent Transformer Model for Clinical Feedback in Surgical Skill Assessment

arXiv.org Artificial Intelligence

In surgical skill assessment, Objective Structured Assessments of Technical Skills (OSATS scores) and the Global Rating Scale (GRS) are established tools for evaluating the performance of surgeons during training. These metrics, coupled with feedback on their performance, enable surgeons to improve and achieve standards of practice. Recent studies on the open-source dataset JIGSAW, which contains both GRS and OSATS labels, have focused on regressing GRS scores from kinematic signals, video data, or a combination of both. In this paper, we argue that regressing the GRS score, a unitless value, by itself is too restrictive, and variations throughout the surgical trial do not hold significant clinical meaning. To address this gap, we developed a recurrent transformer model that outputs the surgeon's performance throughout their training session by relating the model's hidden states to five OSATS scores derived from kinematic signals. These scores are averaged and aggregated to produce a GRS prediction, enabling assessment of the model's performance against the state-of-the-art (SOTA). We report Spearman's Correlation Coefficient (SCC), demonstrating that our model outperforms SOTA models for all tasks, except for Suturing under the leave-one-subject-out (LOSO) scheme (SCC 0.68-0.89), while achieving comparable performance for suturing and across tasks under the leave-one-user-out (LOUO) scheme (SCC 0.45-0.68) and beating SOTA for Needle Passing (0.69). We argue that relating final OSATS scores to short instances throughout a surgeon's procedure is more clinically meaningful than a single GRS score. This approach also allows us to translate quantitative predictions into qualitative feedback, which is crucial for any automated surgical skill assessment pipeline. A senior surgeon validated our model's behaviour and agreed with the semi-supervised predictions 77 \% (p = 0.006) of the time.


Cognitive-Motor Integration in Assessing Bimanual Motor Skills

arXiv.org Artificial Intelligence

Biomedical Engineering Department, Rensselaer Polytechnic Institute, NY, USA Accurate assessment of bimanual motor skills is essential across various professions, yet, traditional methods often rely on subjective assessments or focus solely on motor actions, overlooking the integral role of cognitive processes. This study introduces a novel approach by leveraging deep neural networks (DNNs) to analyze and integrate both cognitive decision-making and motor execution. We tested this methodology by assessing laparoscopic surgery skills within the Fundamentals of Laparoscopic Surgery program, which is a prerequisite for general surgery certification. Utilizing video capture of motor actions and non-invasive functional near-infrared spectroscopy (fNIRS) for measuring neural activations, our approach precisely classifies subjects by expertise level and predicts FLS behavioral performance scores, significantly surpassing traditional single-modality assessments. In this study, we introduce a novel approach by conducting a direct statistical comparative analysis between neural activations and motor actions for assessing bimanual motor skills using DNNs. We explore the synergy of these modalities in multimodal analysis, applied to precision and cognitive-demanding tasks, particularly within the Fundamentals of Laparoscopic Surgery (FLS) program (Figure 1).